NTPM 100D / 110D
Smart Energy Sensor
9-48 VDC, Ethernet, RS485, 1 Digital Output, 2 Relay outputs, up to 31st Harmonic, Alarms
Electrical characteristics
Power supply
Voltage | 9 – 48 V DC |
Power consumption | Max. 2.5 W |
Voltage inputs
Measured voltage (Un) | Up to 400 V L-N / 690 V L-L (Wye) or 600 V L-L (Delta)
UL listed up to 347 V L-N / 600 V L-L |
Measurement by voltage transformer | Support external VT with ratio up to 350 |
Measurement category | CAT III 600 V per IEC 61010-2-030 |
Frequency range (configurable) | 47 – 53 Hz (50 Hz nominal) |
57 – 63 Hz (60 Hz nominal) | |
Network type | Single-phase / Two-phase / Two-phase with neutral / Three-phase / Three-phase with neutral |
Impedance | 5 MΩ |
Overload | 1.15 Un |
Current inputs
Maximum CT primary | 5000 A |
Rated input current (Ib) | 5 A |
Supported CT | Support external CT with ratio up to 1000 |
Measured current | up to 5000 mA |
Starting current | 0.001 Ib |
Permissible current overload | 6 A continuous |
20 A 10 sec | |
50 A 1 sec | |
Frequency range | 47 – 53 (50 Hz nominal) |
57 – 63 (60 Hz nominal) |
Measuring characteristics
Accuracy class | 0.5 |
Active power measurement precisions class | 0.5 |
Reactive power measurement class | 0.5 |
Power factor (PF) precision class | 0.5 |
Frequency measurement precision class | 0.5 |
Voltage harmonics | up to 31st harmonic |
Current harmonics | up to 31st harmonic |
Sampling rate | 64 samples / cycle |
Relay outputs
Number of outputs | 2 |
Type | General purpose |
Maximum load voltage | 250 V AC / 30 V DC |
Maximum load current | 1 A |
Digital outputs
Number of outputs | 1 |
Type | Form A solid state relay |
Maximum load voltage | 30 V AC / 60 V DC |
Maximum load current | 125 mA |
ON resistance | 8 Ω |
Isolation | 2500 V RMS for 1 minute |
Communication
Interfaces | 10/100 Mbps Ethernet | 1 port |
Modbus TCP, ICMP server, DHCP client, Lan Discovery, Web server | ||
RS 485 | 1 port | |
Modbus RTU | ||
2.5 kV RMS, double isolated | ||
Protocols | Modbus TCP | |
Modbus RTU |
Mechanical characteristics
Dimensions | 88 x 94 x 58 mm (5 modules) | |
Net weight | 300 g | |
Case | Material | Plastic, PC (UL 94 V-0) |
Mounting | 35 mm DIN rail | |
IP degree of protection | <IP40 |
Environment
Operating temperature | -25 to 70 °C |
Storage temperature | -40 to 80 °C |
Relative humidity | 5 to 95 % non-condensing |
Altitude | <2000 m |
Pollution degree | 2 |
EMC (Electromagnetic compatibility)
Harmonic emissions | IEC 61000-3-2 | class A |
Flicker limitations | IEC 61000-3-3 | Compliant |
Immunity to ESD | IEC 61000-4-2 | Level 4 |
Immunity to radiated fields | IEC 61000-4-3 | Level 3 |
Immunity to fast transients | IEC 61000-4-4 | Level 4 |
Immunity to surges | IEC 61000-4-5 | Level 4 |
Conducted RF disturbances | IEC 61000-4-6 | Level 3 |
Immunity to magnetic fields | IEC 61000-4-8 | Level 3 |
Immunity to voltage dips and interruptions | IEC 61000-4-11 | Compliant |
Radiated RF emissions | EN 55011 + EN 55016-2-3 | Class A |
Conducted RF emissions | EN 55011 + EN 55016-2-1 | Class A |
Safety
![]() |
Compliant to Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU |
Standards | EN 61010-1:2010 |
EN 61010-2-030:2010 | |
EN 61326-1:2013 | |
EN 61000-6-2:2005 + AC:2005 | |
EN 61000-6-4:2007 + A1:2011 | |
Protection class | Class II according to EN 61010-1:2010
Double insulated for user accessible parts |
Sustainability
EU RoHS Directive | Compliant |
Toxic heavy metal free | Yes |
Mercury free | Yes |
WEEE | At its end of service life, the product must be disposed of and recycled following specific waste collection regulations on EU markets. |
Datasheet
Manuals
Certificates

Explore more